Call a Specialist Today! (02) 9388 1741
Free Delivery! Free Delivery!

Extreme Networks ExtremeRouting SLX 9740-80C
Next-Generation Fixed Form Router for Core Aggregation at Service Providers and Large Enterprise Data Centers


Extreme Networks ExtremeRouting SLX 9740-80C

Extreme Networks Products
ExtremeRouting SLX 9740
ExtremeRouting SLX 9740 Base Unit with 80 x 100GE/40GE capable QSFP28 ports
Includes 4 AC unpopulated power supply slots, 4 unpopulated fan slots and a 4-post rack mount kit
#SLX9740-80C
Our Price: Request a Quote
ExtremeRouting SLX 9740 Base Unit with 80 x 100GE/40GE capable QSFP28 ports, Front to Back Airflow
Includes 4 fan modules and a 4-post rack mount kit
#SLX9740-80C-AC-F
Our Price: Request a Quote
ExtremeRouting SLX 9740 Base Unit with 80 x 100GE/40GE capable QSFP28 ports, Back to Front Airflow
Includes 4 fan modules and a 4-post rack mount kit
#SLX9740-80C-AC-R
Our Price: Request a Quote
ExtremeRouting SLX 9740 Base Unit with 80 x 100GE/40GE capable QSFP28 ports, Front to Back Airflow, 2 DC Power Supplies
Includes 4 fan modules and a 4-post rack mount kit
#SLX9740-80C-DC-F
Our Price: Request a Quote

Click here to jump to more pricing!

Please Note: All Prices are Inclusive of GST

Overview:

Increasingly organizations are expanding from on-premise, private and hybrid cloud to full multi-cloud architectures to address agility, scale, security, reliability and cost requirements as digital transformation reshapes their business environment. To succeed in the digital era, organizations need network platforms with the adaptability to address these rapidly evolving demands and enable them to simplify and scale operations while driving out cost.

The ExtremeRouting SLX 9740 Series platforms serve as demarcation between the enterprise networks and the service provider networks (Internet) where the ISP connections terminate. Basic requirements include support for a full Internet routing table, mainstream routing protocols BGP, OSPF and IS-IS, EVPN VxLAN, ACLs, BGP Internet peering scale, MPLS, deep buffer, device management and entry level DDoS protection.

Extreme Networks offers a choice for selecting the right routing solution to meetyour business needs. The options include the SLX 9740 (1U) with 40 x 100 GbE port s and the SLX 9740 (2U) with 80 x 100 GbE port s to deliver cost effective solutions for the most demanding Enterprise and Service Provider customers.

Highlights

  • High-density, fixed form factor Router with either 80 x 100 GbE or 40 x 100 GbE port s for ultra-high-end data centers and cross connections for Internet Exchange Points (IXPs)
  • Ultra-deep buffers of up to 16GB to ensure optimal performance to handle traffic in virtually any network for bursty traffic patterns
  • Fully featured Data Center Switch and Router with carrier-class MPLS, VXLAN, and Dual Stack IPv4/IPv6 functionality
  • Integrated Application Hosting supports an open kernel-based virtual machine (KVM) environment to accommodate Extreme-provided or third-party customer specific applications, containers - with complete isolation from the networking operating system
  • Collapsed Campus Core with deep buffer and aggregation with fixed form factor switches with 10/25/40/100 GbE connections
  • BGP EVPN-VXLAN for Data Center Spine and Data Center Interconnect (DCI) networking

Features:


Internet-Scale Routing Platform

The SLX 9740 are high density, fixed form factor router with either 80 x 100 GbE and 40 x 100 GbE ports to deliver the scale and performance needed to address the explosive growth in network bandwidth, devices and services. This platform provides carrier-class advanced features that leverage proven Extreme Networks routing, MPLS, Carrier Ethernet, and VXLAN overlay technology, deployed in the most demanding service providers, internet exchange points (IXPs) and large enterprise data centers.


Border Router with Ultra-Deep Buffers

The border router is the interconnection point between internal networks and the internet. With more traffic moving across these routers, there is added demand for capacity, the ability to absorb speed mismatches and handle microbursts without compromising performance. The SLX 9740 has up to 16GB of deep packet buffers.


Core-Aggregation

Large Enterprise and co-location data center consolidate on multiple layers with the SLX 9740 and can sit as an edge router above the data center network. MPLS or layer 3 protocols link the data center gear to another data center or the outside world. Multi-Chassis Trunking (MCT) provides dynamic flow-based load balancing to multiple networks nodes.


Ultra-Deep Buffers

The SLX 9740 offers a deep buffering platform that is purpose-built for the most demanding service provider and enterprise networks. The border router is the interconnection point between internal networks and the internet. With more traffic moving across these routers, there is added demand for capacity, the ability to absorb speed mis-matches and handle microburst s without compromising performance. The SLX 9740 -40 C has 8GB and SLX 9740 -80 C has 16GB of deep packet buffers.


Integrated Application Hosting

The SLX 9740 can run third-party VM-based applications alongside the routing OS - all without impacting performance. This flexible and open solution enables organizations to deploy Extreme-provided or third-party applications and tools directly on the router. This design does not impact the control plane or forwarding of data traffic.


Internet Exchange Points

The ever-increasing growth of IXPs traffic with new record highs demand wide spread 100 GbE connectivity at the edge of the network. Cost per port is a key factor as customers migrate from 10 GbE to 100 GbE and ultra-high density are essential with the right mix of technologies (e.g. VPLS and EVPN) with the SLX 9740.


Specifications:


  SLX 9740-40C SLX 9740-80C
Maximum 100 GbE/40 GbE ports 40 80
Maximum 10/25 GbE 72 ports in breakout mode (18x4) 144 ports in breakout mode (36x4)
Switch fabric capacity (data rate, full duplex) 4.0 Tbps in each direction
(front panel ports, 40 x10 0 Gbps)
8.0 Tbps in each direction
(front panel ports, 80 x10 0 Gbps)
Forwarding capacity (data rate, full duplex) 2000 Mpps (packet size=284B) 4000 Mpps (packet size=284B)
Airflow Front to back or back to front (orderable option) Front to back or back to front (orderable option)
Fan module slots 6 (5+1redundancy) 4 (3+1redundancy)
Maximum AC power supply rating 1600 W 1600 W
Power Supplies Modular 1600 W AC/DC power supply (up to two PSUs) 1600 W AC/DC power supply (up to two PSUs)
Dimensions Height: 1.7 in / 4.31cm
Width: 17.72 in / 45.00 cm
Depth: 25.2 in / 64.00 cm
Height: 3.41in / 8.66 cm
Width: 17.72 in / 45.00 cm
Depth: 25.2 in / 64.00 cm
Weight 2 PS, 6 fans: 29.98 lb, 13.60 kg
2 PS, 6 fans, rack mount kit (4 post): 36.24 lb, 16.44 kg
No PS, no fan: 23.28 lb, 10.56 kg, Fan: 0.27 lb, 0.13 kg.
PS: 2.54 lb, 1.15 kg
2 PS, 6 fans: 29.98 lb, 13.60 kg
2 PS, 6 fans, rack mount kit (4 post): 36.24 lb, 16.44 kg
No PS, no fan: 23.28 lb, 10.56 kg, Fan: 0.27 lb, 0.13 kg.
PS: 2.54 lb, 1.15 kg
Port type QSFP28 Port Configs: 40x100 GbE, 40x40 GbE, 72x25GbE, 72x10 GbE QSFP28 Port Configs: 40x100 GbE, 40x40 GbE, 72x25GbE, 72x10 GbE
Packet buffers per switch 8 GB 16 GB
Operating Conditions
  • Operating temperature and operating altitude for airflow front to back: 0°C to 40°C (32°F to 10 4°F) /6.600 ft (2,2012m)
  • Operating temperature and operating altitude for airflow back to front: 0°C to 25°C (32°F to 77°F) /1.500 ft (457m)
  • Storage temperature: -25°C to 55°C (-13°F to131°F)
  • Relative humidity: 5% to 90%, at 40°C (104°F), non-condensing
  • Storage humidity: 95% maximum relative humidity, non-condensing
  • Storage altitude: 15,000 ft (4,50 0 m) maximum
Power and Heat Dissipation
Maximum Heat Dissipation (BTU/hr) 3524.74 BTU/hr
(Fans high, all ports 100% traffic, 2 PSU)
6592.26 BTU/hr
(Fans high, all ports 100% traffic, 4 PSU)
Maximum Power Dissipation (Watts) 1033
(Fans high, all ports 100% traffic, 2 PSU)
1932
(Fans high, all ports 100% traffic, 4 PSU)
Acoustic Specifications
Front F-B: 57.3 dBA, re: 20 μPa
B-F: 61.7 dBA, re: 20 μPa
F-B: 61.3 dBA, re: 20 μPa
B-F: 69 dBA, re: 20 μPa
Rear F-B: 60.2 dBA, re: 20 μPa
B-F: 65.1 dBA, re: 20 μPa
F-B: 65.2 dBA, re: 20 μPa
B-F: 70.8 dBA, re: 20 μPa
Right F-B: 50.5 dBA, re: 20 μPa
B-F: 54.9 dBA, re: 20 μPa
F-B: 55.5 dBA, re: 20 μPa
B-F: 62.9 dBA, re: 20 μPa
Left F-B: 51.9 dBA, re: 20 μPa
B-F: 55.9 dBA, re: 20 μPa
F-B: 55.9 dBA, re: 20 μPa
B-F: 64 dBA, re: 20 μPa
Average F-B: 55 dBA, re: 20 μPa
B-F: 59.4 dBA, re: 20 μPa
F-B: 59.5 dBA, re: 20 μPa
B-F: 66.7 dBA, re: 20 μPa
  SLX 9740 Default Profile SLX 9740 Route Profile
Maximum MAC addresses 600,000 190,000
Maximum VLANs 4,096 4,096
Maximum ACLs (IPv4/IPv6/L2) 4,000 IPv4 / 2,000 IPv6 / 2,000 L2 4,000 IPv4 / 2,000 IPv6 / 2,000 L2
Maximum members in a standard LAG 64 64
Maximum number of MCT switches 2 2
Maximum number of Bridge Domains 4,000 4,000
Maximum IPv4 unicast routes 2,000,000 3,500,000
Maximum IPv6 unicast routes 2,000,000 3,500,000
Maximum IPv4 host routes (ARP entries) 102,000 95,000
Maximum IPv6 host routes - route scale 102,000 95,000
Maximum jumbo frame size 9,216 bytes 9,216 bytes
QoS priority queues (per port) 8 8

IEEE Compliance

  • Ethernet
    • 802.3-20 0 5 CSMA/CD Access Method and Physical Layer Specifications
    • 802.3ab 1000BASE-T
    • 802.3ae 10 Gigabit Ethernet
    • 802.3u 10 0BASE-TX, 10 0BASE-T4, 10 0BASE-FX Fast Ethernet at 10 0 Mbps with Auto-Negotiation
    • 802.3x Flow Control
    • 802.3z 1000BASE-X Gigabit Ethernet over fiber optic at 1Gbps
    • 802.3ad Link Aggregation
    • 802.1Q Virtual Bridged LANs
    • 802.1D MAC Bridges
    • 802.1w Rapid STP
    • 802.1s Multiple Spanning Trees
    • 802.1ag Connectivity Fault Management(CFM)
    • 802.3.bj 10 0 Gigabit Ethernet
    • 802.1ab Link Layer Discovery Protocol
    • 802.1x Port-Based Network Access Control
    • 802.3ah Ethernet in the First Mile Link OAM3
    • ITU-T G.80 13/y.1731OAM mechanisms for Ethernet
    • G.8032
  • General Protocols
    • RFC 768 UDP
    • RFC 791IP
    • RFC 792 ICMP
    • RFC 793 TCP
    • RFC 826 ARP
    • RFC 854 TELNET
    • RFC 894 IP over Ethernet
    • RFC 903 RARP
    • RFC 906 TFTP Boot strap
    • RFC 950 Subnet
    • RFC 951BootP
    • RFC 1027 Proxy ARP
    • RFC 1042 Standard for The Transmission of IP
    • RFC 1166 Internet Numbers
    • RFC 1122 Host Extensions for IP Multicasting
    • RFC 1191Path MTU Discovery
    • RFC 1340Assigned Numbers
    • RFC 1519 CIDR
    • RFC 1542 BootP Extensions
    • RFC 1591DNS (client)
    • RFC 1812 Requirement s for IPv4 Routers
    • RFC 1858 Security Considerations for IP Fragment Filtering
    • RFC 2131BootP/DHCP Helper
    • RFC 2578 Structure of Management Information Version 2
    • RFC 2784 Generic Routing Encapsulation
    • RFC 3021Using 31-Bit Prefixes on IPv4 Point-to-Point Links
    • RFC 3768 VRRP
    • RFC 4001 Textual Conventions for Internet Network Addresses
    • RFC 4950 ICMP Extensions for MPLS
    • RFC 5880 Bidirectional Forwarding Detection
    • RFC 5881Bidirectional Forwarding Detection for IPv4 and IPv6 (Single Hop)
    • RFC 5882 Generic Application of Bidirectional Forwarding Detection
    • RFC 5884 Bidirectional Forwarding Detection for Multihop Paths
    • Egress ACL Rate Limiting
  • BGP4
    • RFC 1745 OSPF Interactions
    • RFC 1772 Application of BGP in the Internet
    • RFC 1997 Communities and Attributes
    • RFC 2385 BGP Session Protection via TCP MD5
    • RFC 2439 Route Flap Dampening
    • RFC 2918 Route Refresh Capability
    • RFC 3392 Capability Advertisement
    • RFC 3682 Generalized TTL Security Mechanism for eBGP Session Protection
    • RFC 4271BGPv4
    • RFC 4364 BGP/MPLS IP Virtual Private Networks
    • RFC 4456 Route Reflection
    • RFC 4486 Sub Codes for BGP Cease Notification Message
    • RFC 4724 Graceful Restart Mechanism for BGP
    • RFC 6793 BGP Support for Four-octet AS Number Space
    • RFC 5065 BGP4 Confederations
    • RFC 5291Outbound Route Filtering Capability for BGP-4
    • RFC 5396 Textual Representation of Autonomous System (AS) Numbers
    • RFC 5668 4-Octect AS specific BGP Extended Community
    • draft-ietf-rtgwg-bgp-pic-07.t xt - BGP Prefix Independent Convergence
    • RFC 5575 Dissemination of Flow Specification Rules (BGP Flow Spec)
    • RFC 8092 BGP Large Community Attribute
    • sFlow BGP AS path
  • OSPF
    • RFC 1745 OSPF Interactions
    • RFC 1765 OSPF Database Overflow
    • RFC 2154 OSPF with Digital Signature (Password,MD-5)
    • RFC 2328 OSPF v2
    • RFC 3101OSPF NSSA
    • RFC 3137 OSPF Stub Router Advertisement
    • RFC 3630 TE Extensions to OSPF v2
    • RFC 3623 Graceful OSPF Restart
    • RFC 4222 Prioritized Treatment of Specific OSPF Version2
    • RFC 5250 OSPF Opaque LSA Option
  • IS-IS
    • RFC 1195 Routing inTCP/IP and Dual Environment s
    • RFC 1142 OSI IS-IS Intra-domain Routing Protocol
    • RFC 3277 IS-IS Blackhole Avoidance
    • RFC 5120 IS-IS Multi-Topology Support
    • RFC 530 1Dynamic Host Name Exchange
    • RFC 5302 Domain-wide Prefix Distribution
    • RFC 5303 Three-Way Handshake for IS-IS Point-to-Point
    • RFC 5304 IS-IS Cryptographic Authentication(MD-5)
    • RFC 5306 Restart Signaling for ISIS (helper mode)
    • RFC 5309 Point-to-point operation over LAN in link state routing protocols
  • IPv4 Multicast
    • RFC 1112 IGMP v1
    • RFC 2236 IGMP v2
    • RFC 4601PIM-SM
    • RFC 4607 PIM-SSM
    • RFC 4610 Anycast RP using PIM
    • RFC 5059 BSR for PIM
    • PIM IPv4 (MCT future)
  • QOS
    • RFC2474 DiffServ Definition
    • RFC2475 An Architecture for Differentiated Services
    • RFC 2597 Assured Forwarding PHB Group
    • RFC 2697 Single Rate Three-Color Marker
    • RFC 2698 ATwo-RateThree-Color Marker
    • RFC 3246 An Expedited Forwarding PHB
  • IPv6 Core
    • RFC 1887 IPv6 unicast address allocation architecture
    • RFC 1981IPv6 Path MTU Discovery
    • RFC 2375 IPv6 Multicast Address Assignment s
    • RFC 2450 Proposed TLA and NLA Assignment Rules
    • RFC 2460 IPv6 Specification
    • RFC 4862 IPv6 Stateless Address - Auto Configuration
    • RFC 2464 Transmission of IPv6 over Ethernet Networks
    • RFC 2471IPv6 Testing Address allocation
    • RFC 2711IPv6 Router Alert Option
    • RFC 3587 IPv6 Global Unicast? Address Format
    • RFC 4193 Unique Local IPv6 Unicast Addresses
    • RFC 4291IPv6 Addressing Architecture
    • RFC 4301IP Security Architecture
    • RFC 4303 Encapsulation Security Payload
    • RFC 4305 ESP and AH cryptography
    • RFC 4443 ICMPv6
    • RFC 4552 Auth for OSPFv3 using AH/ESP
    • RFC 4835 Cryptographic Alg. Req. for ESP
    • RFC 4861Neighbor Discovery for IP version 6 (IPv6)
    • RFC 3315 Dynamic Host Configuration Protocol for IPv6 (DHCPv6)
  • IPv6 Routing
    • RFC 5340 OSPF for IPv6
    • RFC 2545 Use of BGP-MP for IPv6
    • RFC 5308 Routing IPv6 with IS-IS
    • RFC 6106 Support for IPv6 Router Advertisement s with DNS Attributes
    • RFC 6164 Using 127-Bit IPv6 Prefixes on Inter-Router Links
  • MPLS
    • RFC 2205 RSVP v1Functional Specification
    • RFC 2209 RSVP v1Message Processing Rules
    • RFC 2702 TE over MPLS
    • RFC 2961RSVP Refresh Overhead Reduction Extensions
    • RFC 3031MPLS Architecture
    • RFC 3032 MPLS Label Stack Encoding
    • RFC 3037 LDP Applicability
    • RFC 3097 RSVP Cryptographic Authentication
    • RFC 3209 RSVP-TE
    • RFC 3270 MPLS Support of Differentiated Services
    • RFC 3478 LDP Graceful Restart
    • RFC 3815 Definition of Managed Object s for the MPLS, LDP
    • RFC 4090 Fast Reroute Extensions to RSVP-TE for LSP Tunnels
    • RFC 4364 BGP/MPLS IP Virtual Private Networks
    • RFC 4379 OAM
    • RFC 4448 Encapsulation methods for transport of Ethernet over MPLS networks
    • RFC 5036 LDP Specification
    • RFC 5305 ISIS-TE
    • RFC 5443 LDP IGP Synchronization
    • RFC 5561LDP Capabilities
    • RFC 5712 MPLS Traffic Engineering Soft Preemption
    • RFC 5918 LDP ?Typed Wildcard? FEC
    • RFC 5919 Signaling LDP Label Advertisement Completion
  • Layer 2 VPN and PWE3
    • RFC 3343 TTL Processing in MPLS networks
    • RFC 3985 Pseudowire Emulation Edge to Edge (PW E3) Architecture
    • RFC 4364 BGP/MPLS IP Virtual Private Networks
    • RFC 4447 Pseudowire Setup and Maintenance using LDP
    • RFC 4448 Encapsulation Methods for Transport of Ethernet over MPLS Networks
    • RFC 4664 Framework for Layer 2 Virtual Private Networks
    • RFC4665 Service Requirement s for Layer 2 Provider-Provisioned Virtual Private Networks
    • RFC4762 VPLS using LDP Signaling
    • RFC 5542 Definitions of Textual Conventions for Pseudowire (PW ) Management
    • RFC 6391Flow-Aware Transport of Pseudowires
    • RFC 6870 PW Preferential Forwarding Status Bit
    • RFC7432BGP MPLS-Based Ethernet VPN -Partial
    • RFC 7348 Virtual eXtensible Local Area Network (VXLAN): A Framework for Overlaying Virtualized Layer 2 Networks over Layer 3 Networks (Partial)
    • draft-sd-l2vpn-evpn-overlay-03 (A Network Virtualization Overlay Solution using EVPN) Partial
    • draft-ietf-bess-evpn-overlay-04 (A Network Virtualization Overlay Solution using EVPN with VXLAN encapsulation) Partial
    • draft-ietf-bess-evpn-overlay-12 A Network Virtualization Overlay Solution using EVPN
    • draft-ietf-bess-evpn-igmp-mld-proxy-00(IGMP and MLD Proxy for EVPN)

Management and Visibility

  • Integrated industry-standard Command Line Interface (CLI)
  • RFC 854 Telnet
  • RFC 2068 HTTP
  • RFC 2818 HTTPS
  • RFC 3176 sFlowv5
  • sFlow extension to VXLAN
  • RFC 4253 Secure Shell (SSH)
  • Secure Copy (SCPv2)
  • SFTP
  • RFC 8040 RESTCONF Protocol -PATCH, PUT, POST, DELETE support.
  • RFC 5905 Network Time Protocol Version 4
  • RFC 3986 Uniform Resource Identifier (URI): GenericSyntax
  • RFC 6241NETCONF Configuration Protocol (Partial)
  • RFC4742 - "Using the NETCONF Configuration Protocol over Secure Shell (SSH)"
  • RFC 6020,"YANG- A Data Modeling Language for the Network Configuration Protocol (NETCONF)"
  • RFC 6021, "CommonyANG DataTypes"
  • RFC4741NETCONF (Partial)
  • Chrome
  • Curl
  • SNMP Infrastructure (v1, v2c, v3)
  • RFC 1157 Simple Network Management Protocol
  • RFC 1908 Coexistence between Version 1and Version 2 of the Internet-standard Network Management Framework
  • RFC 2578 Structure of Management Information Version 2
  • RFC 2579 Textual Conventions for SMIv2
  • RFC 2580 Conformance Statement s for SMIv2
  • RFC 3410 Introduction and Applicability Statement s for Internet Standard Management Framework
  • RFC 3411An Architecture for Describing SNMP Management Frameworks
  • RFC 3412 Message Processing and Dispatching
  • RFC 3413 SNMP Applications
  • RFC 3414 User-based Security Model
  • RFC 3415 View-based Access Control Model
  • RFC 3416 Version 2 of SNMP Protocol Operations
  • RFC 3417 Transport Mappings
  • RFC 3418 Management Information Base (MIB) for the SNMP
  • RFC 3584 Coexistence between Version1, Version2, and Version3 of the Internet-standard Network Management Framework
  • RFC 3826 The Advanced Encryption Standard (AES) Cipher Algorithm in the SNMP User-based Security Model
  • SNMP MIBs
  • IANA-ADDRESS-FAMILY-NUMBERS-MIB
  • IANA if Type-MIB
  • sFlow v5 MIB
  • RFC 1213 Management Information Base for Network Management of TVP/IP based internet s v5 MIB
  • RFC 2674 Bridge MIB
  • RFC 2790 Host Resource MIB
  • RFC2819 RMON Groups 1, 2, 3, 9
  • RFC 2863 The Interfaces Group MIB (IF)
  • RFC 3289 Diffserv MIB
  • RFC 3635 Etherlike InterfaceType MIB
  • RFC 3811MPLS TCSTD MIB
  • RFC 3812 MPLS TESTD MIB
  • RFC 3813 MPLS LSR MIB
  • RFC 4001Textual Conventions for Internet Network Addresses
  • RFC4022 Textual Conventions for Internet Network Addresses (TCP)
  • RFC 4113 Management Information Base for the User Datagram Protocol (UDP)
  • RFC 4133 Entity MIB
  • RFC 4273 BGP-4 MIB
  • RFC 4292 IP Forwarding Table MIB (IP-FORWARD)
  • RFC 4293 Management Information Base for the Internet Protocol (IP)
  • RFC 4444 IS-IS MIB
  • RFC 4750 OSPF v2 MIB
  • RFC 4878 DOT3-OAM-MIB
  • RFC 7257 VPLS MIB (Partial)
  • RFC 7331BFD MIB
  • IEEE/MEF MIBs
  • IEEE-802 LLDP MIB
  • MEF-SOAM-PM-MIB
  • IEEE-8021-CFM-MIB
  • IEEE-8021-CFM-V2-MIB
  • 3rd party Applications,like e.g. TCPdump, Wireshark and PerfSONAR

Element Security

  • AAA
  • Username/Password (Challenge and Response)
  • Bi-level Access Mode (Standard and EXEC Level)
  • Role-Based Access Control (RBAC)
  • RFC 2865 RADIUS
  • RFC 2866 RADIUS Accounting
  • TACACS/TACACS+draft-grant-tacacs-02TACACS+ - Command Authorization, Authentication, Accounting
  • RFC 5905 NTP Version 4 NTP date
  • RFC 5961TCP Security
  • RFC 4250 Secure Shell (SSH) Protocol Assigned Numbers
  • RFC 4251Secure Shell (SSH) Protocol Architecture
  • RFC 4252 Secure Shell (SSH) Authentication Protocol
  • RFC 4253 Secure Shell (SSH ) Transport Layer Protocol
  • RFC 4254 Secure Shell (SSH) Connection Protocol
  • RFC 4344 SSH Transport Layer Encryption Modes
  • RFC 4419 Diffie-Hellman Group Exchange for the Secure Shell (SSH) Transport Layer Protocol
  • draft-ietf-secsh-filexfer-13.t xt SSH File Transfer Protocol (SFTP)
  • Secure Copy (SCP v2) (see RFC4251)
  • RFC 2068 HTTP
  • RFC 4346 TLS 1.1
  • RFC 5246 TLS 1.2
  • Protection against Denial of Service (DoS) attacks such as TCP SYN or Smurf Attacks

Environmental Regulatory Compliance

  • EU RoHS - 2011/65/EU
  • EU W EEE - 2012/19/EU
  • EU REACH - Regulation (EC) No 1907/2006 - Reporting
  • China RoHS - SJ/T 11363-2006
  • Taiwan RoHS CNS 15663(2013.7)

Regulatory and Safety

  • North American ITE
    • CAN/CSA C22.2 NO. 60950-1-01, CAN/CSA C22.2 NO. 62368-1-14
    • CAN/CSA C22.2 NO. 60950-1-01, CAN/CSA C22.2 NO. 62368-1-14
    • UL60950-1, UL 62368-1
  • European ITE
    • EN 60950-1
    • EN 62368-1
    • EN 60825-1Class 1(Lasers Safety)
    • 2014/35/EU Low Voltage Directive
  • International ITE
    • CB Report & Certificate per IEC 60950-1+ National Differences
    • CB Report & Certificate IEC 62368-1
    • AS/NZS 60950-1(Australia/New Zealand)
  • European ITE
    • ETS 300132-1Equipment Requirement s for AC Power Equipment Derived from DC Sources
    • ETS 300132-2 Equipment Requirement s for DC Powered Equipment
    • ETS 300253 Facility Requirement s
    • ETS 300253 Facility Requirement s
  • EMI/EMC Standards
    • FCC CFR 47 part 15 Class A (USA)
    • ICES-003 Class A (Canada)
  • European EMC Standards
    • EN 55032 Class A
    • EN 55024
    • EN 55011
    • EN 61000-3-2: (Harmonics)
    • EN 61000-3-3 (Flicker)
    • EN 300386 (EMC Telecommunications)
    • 2014/30/EU EMC Directive
  • International EMC Standards
    • CISPR 32 Class A (International Emissions)
    • AS/NZS CISPR32
    • CISPR 24 Class A (International Immunity)
    • IEC 61000-4-2/EN 61000-4-2 Electrostatic Discharge, 8kV Contact, 16kV Air, Criteria B
    • IEC 61000-4-3/EN 61000-4-3 Radiated Immunity 10V/m, Criteria A
    • IEC 61000-4-4 /EN 61000-4-4 Transient Burst, 2kV, Criteria B
    • IEC 61000-4-5/EN 61000-4-5 Surge, 1kV L-L, 2kV L-G, Level 3 Criteria B
    • IEC 61000-4-6/EN 61000-4-6 Conducted Immunity, 0.15-80Mhz, 10Vrms, 80%AM (1kHz) Criteria A
    • IEC/EN 61000-4-11Power Dips & Interruptions, >30%, 25 periods, Criteria C
  • Country Specific
    • VCCI Class A (Japan Emissions)
    • ACMA RCM (Australia Emissions)
    • CCC Mark
    • KCC Mark, EMC Approval (Korea)
    • BSMI (Taiwan)
    • Anatel (Brazil)
    • NoM (Mexico)
    • EAC (Russiam Belarus, Kazhakstan)
    • NRCS (South Africa)
  • Physical Design and Mountin
    • 19-inch rack mount supporting racks compliant with: -ANSI/EIA-310-D


Documentation:

Download the Extreme Networks ExtremeRouting SLX 9740 Datasheet (.PDF)

It appears you don't have a PDF plugin for this browser. No biggie... you can click here to download the PDF file.

Pricing Notes:

Extreme Networks Products
ExtremeRouting SLX 9740
ExtremeRouting SLX 9740 Base Unit with 80 x 100GE/40GE capable QSFP28 ports
Includes 4 AC unpopulated power supply slots, 4 unpopulated fan slots and a 4-post rack mount kit
#SLX9740-80C
Our Price: Request a Quote
ExtremeRouting SLX 9740 Base Unit with 80 x 100GE/40GE capable QSFP28 ports, Front to Back Airflow
Includes 4 fan modules and a 4-post rack mount kit
#SLX9740-80C-AC-F
Our Price: Request a Quote
ExtremeRouting SLX 9740 Base Unit with 80 x 100GE/40GE capable QSFP28 ports, Back to Front Airflow
Includes 4 fan modules and a 4-post rack mount kit
#SLX9740-80C-AC-R
Our Price: Request a Quote
ExtremeRouting SLX 9740 Base Unit with 80 x 100GE/40GE capable QSFP28 ports, Front to Back Airflow, 2 DC Power Supplies
Includes 4 fan modules and a 4-post rack mount kit
#SLX9740-80C-DC-F
Our Price: Request a Quote